Method Article
A method to quantify micro- and nano-plastics originating from polybutylene adipate terephthalate in soil using nuclear magnetic resonance spectroscopy is described here. This technique improves on existing methodology because it extends to quantification of nanoplastics and it can easily be adapted for processing environmental samples in bulk.
A method to recover and quantify micro- and nano-plastics (MPs and NPs) formed in the soil during biodegradation is needed to accurately assess the degradation and environmental impact of biodegradable plastic products. The presence of MPs and NPs in soil may alter soil properties like aggregation behavior or have toxic effects on soil biota. Existing MP recovery methods are not always suitable for measuring biodegradable polymers like polybutylene adipate terephthalate (PBAT); some common digestion procedures with acids or oxidizers can destroy PBAT-based biodegradable MPs. Identification methods like micro-FTIR and micro-Raman spectroscopy are also limited by the minimum size of particles that can be recovered and analyzed. Therefore, this method was developed to extract and quantify PBAT from soil to assess the mass fraction of MPs and NPs in the soil without chemically transforming PBAT. In the protocol, a chloroform-methanol solution is used to selectively extract PBAT from the soil. The solvent is evaporated from the extract, and then the extract is redissolved in deuterated chloroform. The extract is analyzed by proton nuclear magnetic resonance spectroscopy (1H-QNMR) under quantitative parameters to quantify the amount of PBAT in each sample. Solvent extraction efficiencies for PBAT range from 76% in a shady loam soil to 45% in an Elkhorn sandy loam soil. PBAT recovery may be reduced for photo-oxidized materials compared to pristine ones and may be reduced in soils with high clay content. Extraction efficiencies do not depend on PBAT concentration within the test range, but lower extraction efficiencies were observed for NPs than for MPs. PBAT quantification results were comparable to the quantification of plastic degradation by measuring cumulative soil respiration in a laboratory incubation study.
Methods to measure MP contamination in soil are necessary to understand the scope of plastic contamination in global soils1, sources of plastic contamination2, and potential solutions3. Agricultural soils are uniquely exposed to plastic contamination: more than 15 million metric tons of plastic are used in agriculture each year as of 20214, including 2.5 million tons of plastic mulch5. Plastic mulch is used in close contact with soil, reapplied one or more times per year6, and can be difficult to fully remove from soil after their useful life7. One key area where MP measurement methods are needed is in the assessment of biodegradable plastic products like biodegradable plastic mulches for use in vegetable systems8.
Biodegradable-in-soil plastic products are promising alternatives to conventional agricultural plastics because they could eliminate plastic contamination of soil by plastic mulching if they work as intended. In 2022, less than 1 million metric tons of biodegradable plastic were produced globally, with rapid growth expected for the industry9. The four most common biodegradable polymers, polylactic acid (PLA), polymerized starch, polyhydroxyalkanoates (PHA), and polybutylene adipate terephthalate (PBAT), are all used commercially or experimentally in agricultural biodegradable plastic mulches10. Despite their promise, the degradation of these biodegradable plastic products in field conditions is variable11. While some studies of biodegradable plastic mulch degradation in the field have focused on macroplastic fragments11, assessing the complete degradation of plastic materials requires the ability to recover MPs and NPs from soil. Microplastic quantification from soil is also important to assess the potential for negative impacts on soil ecosystems from MP pollution12.
Some commonly used techniques for MP identification and quantification include visual analysis, micro-Fourier-transformed infrared spectroscopy (µFTIR), micro-Raman spectroscopy (µRaman), gas chromatography-mass spectroscopy (GCMS including pyrolysis GCMS and thermal extraction desorption GCMS), and thermogravimetric analysis13. Other developing techniques include near-infrared spectroscopy for in situ MP measurement in soils14, fatty acid methyl esterification extraction for GCMS analysis15, and nuclear magnetic resonance spectroscopy16. As many as 90% of studies quantifying MPs in soil used visual analysis (alone or paired with other techniques) to identify plastic particles, while 77% used FTIR, Raman, or GCMS spectroscopy techniques17. Developing and harmonizing a diverse variety of MP quantification techniques can help expand the scientific community's ability to answer diverse microplastic research questions18. Three generic approaches exist to prepare soil samples to quantify microplastics: 1) separating unchanged individual microplastic particles from the soil (ex. by density separation), 2) extracting transformed plastic or polymer material (ex. by dissolution), or 3) analyzing bulk soil. Both µFTIR and µRaman spectroscopy require individual MPs to be separated from the soil before they can be chemically identified19 while pyro-GCMS may be performed on isolated plastic particles separated from soil or bulk soil20. Separating biodegradable MPs from soil can be difficult because some digestions used to remove soil organic matter can degrade or otherwise chemically alter biodegradable polymers, including PBAT21. Micro-Raman and µFTIR spectroscopy both also have a spatial resolution limit: particles must be larger than 10-20 µm for µFTIR and 1 µm for µRaman (if individual particles this small can be prepared for analysis)19,22. These techniques can provide chemical identification of MP polymers, and spectroscopic imaging can be employed to measure MP size22. All types of pyro-GCMS are limited in that samples are destroyed during analysis.
NMR has been used successfully to characterize soil constituents and contaminants23, to quantify MPs16,24,25,26, and to assess the degradation of PBAT and another polymer, polystyrene27,28. When run under quantitative parameters, 1H-NMR spectroscopy produces spectra where the area of each spectral peak is directly proportional to the number of contributing hydrogens in the sample; this allows for quantification of the constituent components in a sample29. NMR is a valuable analytical technique for quantifying some MPs, including PBAT, within soil because it allows for simultaneous quantification and identification, it is suitable for complex and impure mixtures, and it does not require chemically identical reference standards30,31. NMR spectroscopy of a solvent extract could quantify MPs or NPs smaller than those that can be processed for µFTIR, µRaman, or GCMS quantification. Despite these advantages, quantitative NMR approaches still provide lower sensitivities than destructive mass spectroscopy-based approaches32.
The proposed method, diagramed in Figure 1, describes a workflow to process and analyze soil samples containing PBAT - including nano-sized PBAT plastics. In the method, PBAT polymer is extracted from soil samples by shaking the soil with a mixture of chloroform and methanol. The solvent extracts containing PBAT are dried and then redissolved in deuterated chloroform with an added internal calibrant. NMR spectroscopy is conducted on the extracts using quantitative parameters. The resulting spectra are analyzed to quantify PBAT by comparing the area of fitted peaks corresponding to hydrogen atoms of the PBAT and calibrant molecules. This method applies the solvent extraction and proton nuclear magnetic resonance spectroscopy (1H-NMR) approach demonstrated by Nelson et al.33. The goal was to employ a method suitable to process environmental scale samples (~100 g of soil) and to process a number of samples in parallel without specialized extraction equipment.
1. Collection and preparation of soil
NOTE: Sampling and processing equipment should not contain the polymer PBAT or its constituents to avoid sample contamination. Other polymer materials do not necessarily interfere with the quantification of PBAT from the soil. For example, polyethylene and polypropylene do not produce spectral peaks in chloroform 1H-NMR which interfere with the quantification of PBAT34, but polyethylene terephthalate, with its terephthalate group, most likely would interfere35, as could other polyesters. Reference texts like Brandolini and Hills34 can be used to determine the 1H-NMR spectra of various polymers and screen for overlapping peaks with the PBAT peaks used for quantification (described below).
2. Extraction of PBAT from soils
CAUTION: Chloroform is volatile and toxic. Store it in the dark in amber glass, away from oxidizers. While working with it, wear appropriate gloves, eye protection, and protective clothing. Handle it only in a fume hood. Methanol is flammable, volatile, and toxic. Store methanol in a fire-proof cabinet. While working with methanol, wear appropriate gloves, eye protection, and protective clothing. Handle methanol only in a fume hood. Glassware may break and cause injury. Wear eye protection when handling glassware. Avoid touching broken glass with bare hands. Instead, clean up broken glass with cut-resistant gloves, tongs, broom, or another tool.
NOTE: Chloroform is not compatible with most plastics or metals. Ensure that all materials are compatible (e.g., glass or polytetrafluoroethylene, PTFE plastic).
3. Collection of NMR spectra
CAUTION: Deuterated chloroform poses the same risks and requires the same precautions as protonated chloroform described above.
4. Analysis of NMR spectra to quantify PBAT
NOTE: Spectral analysis may be conducted at any time after collection. Analyzing data the same day as spectra are produced is preferred to ensure samples are still available to rerun in case of any issues.
5. Preparation of calibration curve for quantification of PBAT from a particular soil
NOTE: A calibration curve created based on soil samples with known amounts of PBAT added will provide useful information about how PBAT is extracted and recovered from a particular soil. Extraction is not the same for all soils or all forms of PBAT. We suspect extraction efficiency is dependent on soil clay and organic matter content33, and recommend creating a calibration curve for each soil series and horizon of interest. The calibration curve can be created before or after unknown samples are processed with this method.
To assess the efficacy of this method in quantifying PBAT polymer from the soil, calibration curves were constructed by extracting PBAT from spiked samples created from three different soils. For each of the three soils (details in Table 3), the soil was passed through a 2 mm sieve and then air dried. Spiked samples were created by adding 0, 9, 18, 27, or 36 mg of PBAT-based MP to 100 g of dry soil (5 replicates of each). This is equivalent to 0, 63, 126, 189, or 252 mg/kg of PBAT polymer. MPs were made from plastic mulch with 70% PBAT by mass and 50 µm thickness according to the grinding procedure described in Astner et al.45 and were smaller than 840 µm. To create each calibration curve, PBAT was extracted from each spiked sample following the procedure defined above. The recovery of PBAT was then compared to the amount of PBAT added to each sample. PBAT recovery rate and quantification were also tested for NPs (mean diameter 780 nm, polydispersity index 0.77, prepared according to Astner et al.45) in one soil (Shady loam).
For all soils, no PBAT was detected in samples with no PBAT added, i.e., there were no false positives observed by this method. Supplementary Figure 1 shows a spectrum collected from a Shady loam soil that did not contain PBAT (and did contain DMB added during the preparation process). The two characteristic peaks from the internal calibrant DMB are present, but PBAT characteristic peaks are not. For soils with PBAT added, the five characteristic peaks used to identify PBAT were present. Figure 2 shows a spectrum collected from a Shady loam soil with 63 mg/kg of PBAT added. All PBAT and DMB peaks used in quantification are clearly resolved. Supplementary Figure 2 shows the fitted region of the spectrum shown in Figure 2 with integrated peaks overlaid. Because of the overlap of 3, 3', 6, and 6' peaks with other signals in the spectrum, it is important to calculate PBAT content based on the integrals of fitted peaks rather than simple peak integrals. This removes the area contributed by other constituents of the soil extract and from overlapping PBAT peaks. Supplementary Figure 3 shows the effects of dilution on NMR spectral resolution. The figure shows a spectrum collected from an Elkhorn sandy loam with 252 mg/kg of PBAT added. In panel A, the 3, 3', 6, and 6' PBAT peaks in the 4.5 - 4.0 ppm range cannot be resolved. Supplementary Figure 3B shows a spectrum collected from the same sample after it was diluted by 1:5 with additional deuterated chloroform. After dilution, the four peaks are distinct, and their area can be fit.
Calibration curves varied between the three soils we tested. Figure 4 shows the estimated PBAT concentrations of each soil based on the PBAT measured (CPBAT,m) in each extract compared to the actual amount of PBAT (CPBAT,a) added to the soil. The amount of PBAT recovered from Shady loam soils was strongly correlated with the amount of PBAT added (r2 = 0.99). For the calibration curve equation CPBAT,m = m*CPBAT,a, m = 0.76 ± 0.02 (mean ± one standard error), and m was significantly different from zero (df = 24; F = 2000; p < 1*10-16). PBAT was recovered at an efficiency of η = 76 % ± 10 % (mean ± one standard deviation) from this soil. Extraction efficiency from the Shady soil was not correlated with the amount of PBAT in samples (r2 = 0.009; p = 0.7). NP was recovered at an efficiency of η = 59 % ± 8 % (mean ± one standard deviation). Figure 5 shows the extraction efficiency of MPs and NPs from the Shady loam; efficiency was significantly lower for NP (p = 0.0002). The amount of PBAT recovered from the Los Osos loam was less strongly correlated with the amount of PBAT added (r2 = 0.85) than in the Shady soil. For the calibration curve equation CPBAT,m = m*CPBAT,a, m = 0.57 ± 0.05 (mean ± one standard error), and m was significantly different from zero (df = 23; F = 100; p = 8*10-11). PBAT was recovered at an efficiency of η = 57 % ± 22 % (mean ± one standard deviation) from this soil. Extraction efficiency in the Los Osos soil was not correlated with the amount of PBAT in samples (r2 = 0.01; p = 0.6). The amount of PBAT recovered from the Elkhorn sandy loam was strongly correlated with the amount of PBAT added (r2 = 0.88). For the calibration curve equation CPBAT,m = m*CPBAT,a, m = 0.70 ± 0.05 (mean ± one standard error), and m was significantly different from zero (df = 23; F = 200; p = 5*10-12). PBAT was recovered at an efficiency of η = 70 % ± 14 % (mean ± one standard deviation) from this soil. Extraction efficiency was not correlated with the amount of PBAT in samples (r2 = 0.006; p = 0.7) for the Elkhorn soil.
Furthermore, this method was applied to quantify the PBAT in an Elkhorn series soil. In this experiment, Elkhorn soil was collected from two sites within an agricultural field, sieved through a 2 mm sieve, and then air dried. Soil was mixed with PBAT-based mulch MPs (created as described above, diameter < 840 µm), with 50 mg of MPs and 150 g of dry soil in each mesocosm (250 mg/kg of PBAT) to create 5 mesocosms with MPs mixed into the soil from site A and 5 with MPs mixed into the soil from site B (10 total). Five mesocosms composed of soil from each site without added MPs served as a negative control (10 total). Mesocosms were incubated for 6 months to investigate the biodegradation of the PBAT-based mulch MPs. During the incubation, cumulative soil respiration was measured via headspace CO2 concentrations (using an infrared gas analyzer) and used to quantify PBAT degradation. The amount of plastic remaining in the mesocosms at the end of the incubation was calculated as
CFrac from plastic, final = [mPlastic, i / Cfrac plastic - (CCO2, plastic added - CCO2 no plastic)*mdry soil]/(mPlastic, i/ Cfrac plastic)
where mdry soil is the amount of soil in each incubation jar, Cfrac Plastic is the carbon content of the added microplastics, CCO2, plastic added is the cumulative amount of CO2 produced in a mesocosm with plastic added per gram of dry soil, CCO2 no plastic is the amount of CO2 produced in a mesocosm with no plastic added per gram of dry soil, and mplastic, i is the initial mass of the plastic added.
We used bootstrapping to estimate confidence intervals for plastic remaining in soils A and B by calculating plastic remaining with 10,000 theoretical subsamples of random pairings of the 10 experimental mesocosms from each site. At site A, the estimated mean plastic remaining from respiration data was 86%, with a bootstrapped 95% confidence interval range from 62 to >100%. At site B, the estimated mean plastic remaining was 98%, with a 95% confidence interval range from 79 to >100%. At the end of the 6 months, PBAT content was also measured by the extraction and NMR quantification method described in this manuscript (n = 5 for site A and n = 4 for site B). At site A, the estimated mean plastic remaining from NMR data was 79%, with a 95% confidence interval (mean ± 1.96xSE) ranging from 71% to 87%. At site B, the estimated mean plastic remaining was 88%, with a 95% confidence interval range from 71% to 100%. Figure 6 shows the confidence intervals for the plastic content of soil from the two sites estimated by the two different methods. The plastic content estimates from the two methods appear mutually consistent based on the large portion of overlap between each pair of confidence intervals.
Figure 1: Visual overview of the polybutylene adipate terephthalate (PBAT) extraction and quantification procedure. Please click here to view a larger version of this figure.
Figure 2: 1H-NMR spectrum collected in deuterated chloroform solvent with a 500 MHz spectrometer on an extract from a Shady loam soil with polybutylene adipate terephthalate (PBAT) MPs. 1,4-Dimethoxybenzene (DMB) was added to the extract as an internal calibrant before NMR analysis. Both PBAT and DMB characteristic peaks are present in the spectrum. Please click here to view a larger version of this figure.
Figure 3: Structures of polybutylene adipate terephthalate (PBAT) and 1,4-dimethoxybenzene (DMB) with labeled protons. The corresponding structures are shown in Table 1 and Table 2. (A) Structure of one BA-BT unit of PBAT. (B) Structure of T-B-T, T-B-A, and A-B-A triads from PBAT. (C) Structure of DMB. Please click here to view a larger version of this figure.
Figure 4: PBAT concentrations measured by 1H-QNMR in extracts in deuterated chloroform solvent from a Shady loam soil, a Los Osos loam, and an Elkhorn sandy loam containing known amounts of PBAT. Please click here to view a larger version of this figure.
Figure 5: Extraction efficiency of PBAT MPs and NPs from spiked samples in a Shady loam soil. PBAT recovery is significantly lower for NPs (p = 0.0002). The middle line of each box represents the mean of measured data points, while the upper and lower limits of the box reflect Q3 and Q1, respectively. The upper and lower limits of the whiskers reflect the maximum and minimum data points, respectively. Individual data points are shown within the box and whiskers. Please click here to view a larger version of this figure.
Figure 6: Plastic content of two Elkhorn soils was measured by cumulative incubation respiration and by solvent extraction coupled with NMR. For plastic content measured by respiration, the bars represent a bootstrapped 95% confidence interval. For plastic content measured by NMR, the bars represent a 95% confidence interval based on two times the standard error above and below the mean estimate (n = 5 for site a and n = 4 for site b). Please click here to view a larger version of this figure.
Peak ID | Location | Number of protons | Multiplicity | Monomer | used in quantification |
5 | 8.1 | 4 | Singlet | T | yes |
6 | 4.44 | 2 | Triplet | B | yes |
6’ | 4.38 | 2 | Triplet | B | yes |
3’ | 4.15 | 2 | Triplet | B | yes |
3 | 4.09 | 2 | Triplet | B | yes |
1 | 2.34 | 4 | Triplet | A | no |
7 | 1.97 | 2 | Multiplet | B | no |
7’ | 1.87 | 2 | Multiplet | B | no |
4’ | 1.81 | 2 | Multiplet | B | no |
4 | 1.68 | 2 | Multiplet | B | no |
2 | 1.66 | 4 | Multiplet | A | no |
Table 1: 1H-NMR spectral peaks of polybutylene adipate terephthalate (PBAT) in deuterated chloroform solvent. The hydrogens attributed to each peak are labeled in Figure 3. Peak assignments are based on Herrera et al.27.
Peak ID | Location | Number of protons | Multiplicity | Used in quantification |
A | 6.84 | 4 | Singlet | yes |
B | 3.77 | 6 | Singlet | yes |
Table 2: 1H-NMR peaks of 1,4-dimethoxybenzene (DMB) in deuterated chloroform solvent. The hydrogens attributed to each peak are labeled in Figure 3B. Peak assignments are based on Nelson et al.33.
Soil series | Classification | Texture | Total organic carbon | pH | Collection location | Collection depth (cm) |
Shady | Fine-loamy, mixed, subactive, thermic Typic Hapludult | Loam | 1.70% | 6 | Knoxville, Tennessee, USA | 0-5 |
Los Osos | Fine, smectitic, thermic Typic Argixeroll | Loam | 3.00% | 6 | San Luis Obispo, California, USA | 0-5 |
Elkhorn | Fine-loamy, mixed, superactive, thermic Pachic Argixeroll | Sandy loam | 1% | 7 | Watsonville, California, USA | 0-5 |
Table 3: Properties of the three soils that were used to demonstrate the PBAT extraction method.
Supplementary Figure 1: 1H-NMR spectrum collected in deuterated chloroform solvent with a 500 MHz spectrometer on an extract of a Shady loam with no PBAT polymer present. PBAT characteristic peaks are not present, while DMB (added as an internal calibrant) peaks are. Please click here to download this File.
Supplementary Figure 2: Fitted region of the 1H-NMR spectrum as shown in Figure 4. The spectrum was collected in deuterated chloroform solvent. The green background shows the region of the spectrum that was fit. Purple lines show the fitted peaks while red lines show the error (portions of the spectrum signal not included in fitted peaks). PBAT peaks 5, 6, 6', 3', and 3 are included in the fit along with DMB peaks A and B. Please click here to download this File.
Supplementary Figure 3: 1H-NMR spectra in deuterated chloroform solvent collected with a 500 MHz spectrometer on an extract of an Elkhorn sandy loam with PBAT MPs added. Both PBAT and DMB characteristic peaks are present in the spectrum. (A) PBAT peaks cannot be distinguished to quantify the polymer. If sample extracts produce spectra like this, dilute the sample and then use it to collect a new 1H-NMR spectrum. (B) The same extract is diluted so that all spectral peaks are clearly resolved. Please click here to download this File.
We propose a method for solvent extraction of PBAT from soil coupled with 1H-NMR to quantify PBAT in the extract. Key elements of the extraction process include the extraction technique and equipment, the solvent used to extract, and the time requirements. We chose to use an extraction technique that requires relatively simple and inexpensive equipment (glass jars, glass beads, and a shaker table) compared to the Soxhlet extraction and accelerated solvent extraction (ASE) demonstrated by Nelson et al.33. The goal for this method is that many samples can be extracted in parallel to speed in the processing of bulk soil samples. Another advantage of the simple solvent shaking extraction is that larger volumes of soil can be accommodated compared to Soxhlet or ASE approaches, allowing for easier processing of environmentally representative samples13,36. We selected the chloroform-methanol solvent solution based on the successful results presented by Nelson et al.33 and the availability of deuterated chloroform as a 1H-NMR solvent. We tested ultrasonication of solvent-matrix mixtures aligned with the protocol described in Nelson et al.33 compared to the simple solvent shaking method and found no significant difference in PBAT recovery rates between the two methods. We found that 8 h of shaking at 200 rpm was sufficient to break soil aggregates in 100 g of soil matrix for the three soils we tested, while shorter shaking times or lower shaking speeds were insufficient. Settling was then required to recover solvent without soil particles. PBAT recovery was tested with nano-sized plastics, and recovery was significantly lower than that of MPs. This means the method may need further development to accurately quantify environmental samples of unknown NPs, but partial recovery and measurement of NPs is still valuable compared to other size-limited methods, even though particle size information cannot be obtained by this method.
While Nelson et al.33 reported extraction efficiencies near 100% for an ultrasonication extraction method, we found ultrasonication and the shaker-based extraction method described here both led to extraction efficiencies significantly below 100%. We believe this may be due to the effects of environmental weathering, including photooxidation on the plastic mulch. Nelson et al.33 observed significantly reduced extraction efficiency for UV-irradiated PBAT MPs compared to non-weathered material. The plastic we used to test this quantification method was field-weathered in sunlight for a full growing season before it was processed into MPs. Despite the photo-stabilizers added to commercial plastic mulch films, the mulches' polymer's structure changes due to UV-radiation (e.g., chain cross-linking that increases the material's gel content)46 in environmental weathering conditions and degradation of the polymer can change its NMR spectrum47. This may contribute to the lower PBAT recovery rates we observed compared to Nelson et al.33. We also found that PBAT extraction efficiency varied between the three soils we tested. The Shady soil contains mostly low-activity clays, while the other two soils have smectitic (Los Osos) and mixed, superactive (Elkhorn) clays. The presence of high activity and 2:1 clay minerals may have inhibited the solvent extraction of PBAT from those soils33,48 leading to the lower PBAT recovery we observed. We recommend further research that investigates plastic-mineral associations in soil for biodegradable MPs and NPs, including PBAT, as well as conventional non-degradable polymer MPs and NPs. This is important both to understand how MP polymers can be extracted and measured from soil and to understand how they might biodegrade or otherwise affect soil systems.
Key elements of the NMR spectrum acquisition process include the instrument magnet strength, the number of scans used, sample relaxation time between scans, and total measurement time per sample. We used a 500 MHz spectrometer; higher magnetic field strengths provide greater sensitivity and resolution in NMR spectra. The spectral signal-to-noise ratio can be increased by collecting repeated scans of the same sample and adding them together. Collecting n scans will increase the signal-to-noise ratio by a factor of √n but will increase the measurement time by a factor of n29. This means that if a higher signal-to-noise ratio is needed to quantify PBAT in a sample, the number of scans can be increased at the cost of longer sample runtimes. A signal-to-noise ratio of 150 for a particular signal is needed to maintain an error <1% in quantification44. Under our acquisition parameters (instrument, probe, number of scans), around 5 mg of PBAT per sample (or 50 µg PBAT per mL of extract) was necessary to obtain a signal-to-noise ratio of 150 and thereby error <1% in quantification; this concentration is specific to our data collection set-up. This PBAT concentration is higher than the limits of quantification achieved by others using 1H-NMR to quantify other types of MPs in the absence of soil16,24, demonstrating the impact of soil organic matter and other co-extracted compounds on the quantification method. The quantifiable range of PBAT is also limited on the upper end because of the line broadening seen at PBAT concentrations greater than 25 mg per sample (250 µg PBAT per mL of extract), which led to PBAT peak overlap as described in the representative results and shown in Supplementary Figure 3. However, this method allows flexibility in responding to these limitations in order to ensure that samples are quantifiable. The amount of soil used to create extracts can be increased or decreased and extracts can be diluted and reanalyzed to adjust the PBAT concentration to within the optimal range.
Key elements of the process to quantify PBAT based on NMR spectra include the peaks used to quantify PBAT, the use of line fitting to calculate peak areas, and the calibration curve. Conceptually, any pair of PBAT and DMB peaks could be compared to calculate the ratio of the two compounds in a sample. We found the most accurate results when we calculated the BT: DMB ratio as the average of the 5: A peak areas and the 5:B peak areas (normalized by their respective number of protons). PBAT peak 5 only provides quantification of the 1,4-butanediol-terephthalate (BT) monomer, so the area of 3 and 3' peaks (representing the 1,4-butanediol-adipate, or BA, monomer) was compared to the area of 6 and 6' peaks (representing the BT monomer) to quantify the BA groups present in the sample. The amount of BT and BA were added together to represent the total amount of PBAT remaining. It was not possible to use PBAT peak 1 or 2 in BA quantification due to the interference of coextracted compounds (hypothesized to be soil organic matter), which created multiple broad peaks in the 2.7-0.7 ppm range. We explored removing these unwanted signals from spectra with background correction (i.e., subtracting a blank spectrum from each sample spectrum), but we found creating equivalent comparable background and sample spectra without the use of a calibrant to be unreliable. Line fitting was used to calculate the area of fitted peaks rather than integrating the spectral peaks directly. Due to the overlap between PBAT 3 and 3' peaks and between 6 and 6' peaks, this provided more accurate estimates of PBAT content based on preliminary analysis. We recommend the creation of a calibration curve to account for varying recovery rates of PBAT from different soils. PBAT recovery rates were significantly different for one pair, out of the three soils we tested, as indicated by the non-overlapping 95% confidence intervals for calibration curve slope. PBAT recovery in a third soil was not significantly different from either of the other two. In the absence of a mechanistic understanding of how soil composition impacts PBAT recovery, we recommend that calibration curves be created to assess PBAT recovery in each soil series of interest and for each horizon within a soil profile. If calibration curves are found to be statistically similar between soils, the soils can easily be analyzed in combination.
We believe this method can provide a valuable tool to those interested in quantifying PBAT MPs and NPs in soil, especially for quantifying PBAT in a large number of samples collected in similar soils, for instance, in a long-term plastic biodegradation field study. An NMR method for quantifying MPs from soil is valuable because it allows researchers with access to and expertise in NMR to contribute to meeting the needs of the emerging field by answering important questions about the presence and behavior of MPs in soil systems. While access to instrumentation and expertise will likely be some of the first practical concerns limiting researchers' selection of quantification techniques, NMR is not the most efficient or most suitable tool for quantifying microplastics from soil under all conditions. Particle shape and size information cannot be obtained with a solvent extraction technique; if MP shape and size are of interest, researchers would be better served by a technique to identify individual MP particles like FTIR or Raman spectroscopy. One advantage of solvent extraction methods like the ones presented here and in Nelson et al.33 compared to other MP quantification approaches like FTIR, or Raman spectroscopy is that there is conceptually no size limit to the MPs and NPs that can be quantified; solvent extraction may be most beneficial when particle size information is not necessary or when particles of interest are too difficult to separate by other means. Pyrolysis GCMS may be valuable because it has a higher sensitivity than NMR, but results are also subject to matrix effects as PBAT solvent extraction likely is.
We hope that further work will improve the robustness of this method by addressing the coextracted soil constituents that interfere with PBAT peak resolution in the NMR spectra. Further work is also needed to establish the relationship between PBAT plastic weathering and extraction efficiencies through this method, perhaps accompanied by a more detailed understanding of PBAT degradation products and their 1H-NMR spectra. Based on our results and those of Nelson et al.33, this quantification procedure performs best for quantifying unweathered PBAT plastics in soils with low organic matter and without high-activity clays. While we used this method only to quantify PBAT-based MPs from the soil, the solvent extraction and 1H-NMR quantification procedure could be useful to quantify other MPs and NPs from additional soils26,49. Extending the method to MPs made of another polymer requires ensuring the solubility of the polymer in the solvent and identifying characteristic NMR peaks from the polymer in the chosen solvent. It may be necessary to select a new internal calibrant which is soluble in the chosen solvent and which does not produce peaks that overlap with those of the polymer of interest42.
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Thank you to the USDA-NIFA for funding this project through award number 2020-67019-31167 to SMS and to the University of Tennessee Strategic Planning Research Initiatives (SPRINT) program for an internal grant DGH and SMS. The funders had no role in study design, data collection, analysis, interpretation, report writing, or the decision to submit the article for publication.
Name | Company | Catalog Number | Comments |
1,4-dimethoxybenzene | Arcos Organics 99%+ | AC115411000 | 1 mg per sample |
Amber glass bottle with PTFE lined lid (1 L) | Kimble | 5223253C-26 | reusable |
Chloroform; trichloromethane | Fisher Chemical | AA43685M6 | 90 mL per sample; Fisher Optima |
Deuterated chlorform; trichloro(deuterio)methane | Sigma Aldrich | 1034200025 | 1 mL per sample; minimum 99.8% deuterated; stabilized with silver |
Glass beads (3 mm diameter) | Propper Manufacturing | 3000600 | 20 per sample |
Glass extraction jars with PTFE lined lid (~250 mL volume) | Kimble | 5510858B | 2 per sample, reusable |
Graduated cylinder, 1 L, polypropylene | Nalgene | 3662-1000 | reusable |
Graduated cylinder, 500 mL, polypropylene | Nalgene | 3662-0500 | reusable |
Methanol | Fisher Chemical | A412-4 | 20 mL per sample; certified ACS |
Micropipette wth range of 0.5 - 1 mL | Fisher Scientific | 3123000063 | reusable |
NMR spectrometer | Bruker | n/a | 500 MHz instrument |
NMR tube (7 inch height, high-throughput) | Wilmad | WG-1000-7 | 1 per sample |
Platform shaker | Eppendorf, Excella E5 | M1355-0000 | reusable |
Polyethylene pipette tip (10 mL volume) | Eppendorf | 22492098 | 1 per sample, single use |
Polypropylene micropipette tips (1 mL volume) | Fisher Scientific | 02-707-510 | 3 per sample, single use |
Semi-microbalance | Mettler Toledo | 30532226 | reusable |