Newton's second law is applied to obtain the linear momentum in a control volume in a fluid system. According to this law, the rate of change of linear momentum is equal to the sum of external forces acting on the system. When a control volume matches the fluid system at a specific moment, the forces acting on both are identical. Reynolds transport theorem helps explain this by breaking down the system's linear momentum into two components: the rate of change of linear momentum within the control volume and the net flow of linear momentum across the control surface.

As mass moves in and out of the control volume, it carries linear momentum with it, making the transfer of momentum analogous to the flow of mass. For control volumes that are fixed, nondeforming, and stationary, Newton's second law provides an accurate representation of the system's dynamics. It accounts for internal changes in momentum as well as the momentum flowing across the boundaries of the control surface. This theoretical framework is essential in fluid dynamics for analyzing forces, motion, and interactions within well-defined regions of flow, making it applicable to a wide range of engineering problems.

Теги

Linear MomentumControl VolumeNewton s Second LawExternal ForcesReynolds Transport TheoremFluid DynamicsMass FlowMomentum TransferControl SurfaceInternal ChangesSystem DynamicsEngineering Applications

Из главы 18:

article

Now Playing

18.4 : Linear Momentum in Control Volume

Finite Control Volume Analysis

611 Просмотры

article

18.1 : Conservation of Mass in Finite Cotrol Volume

Finite Control Volume Analysis

797 Просмотры

article

18.2 : Conservation of Mass in Fixed, Nondeforming Control Volume

Finite Control Volume Analysis

729 Просмотры

article

18.3 : Conservation of Mass in Moving, Nondeforming Control Volume

Finite Control Volume Analysis

644 Просмотры

article

18.5 : Application of the Linear Momentum Equation

Finite Control Volume Analysis

43 Просмотры

article

18.6 : Moment-of-Momentum Equation

Finite Control Volume Analysis

54 Просмотры

article

18.7 : Conservation of Energy in Control Volume

Finite Control Volume Analysis

368 Просмотры

article

18.8 : Application of the Energy Equation

Finite Control Volume Analysis

401 Просмотры

article

18.9 : Design Example: Forces in Sluice Gate

Finite Control Volume Analysis

187 Просмотры

JoVE Logo

Исследования

Образование

О JoVE

Авторские права © 2025 MyJoVE Corporation. Все права защищены