In the standard form, the transfer function is shown in constant gain, poles/zeros at origin, simple poles/zeros, and quadratic poles/zeros; each contributing uniquely to the system's overall response. The term represents the magnitude of the simple zero:

Equation 1

The Bode magnitude plot remains flat at low frequencies (approaching 0 dB) and begins to ascend at 20 dB/decade after a specific frequency known as the corner or break frequency, ω1. This is the frequency where the magnitude plot's slope changes and the actual response begins to deviate from the straight-line approximation. This deviation is quantified as 3 dB at ω=ω1.

The phase angle ϕ, expressed as:

Equation 2

Phase angle starts at 0° and approaches 90° asymptotically as the frequency increases. For frequencies much lower than the corner frequency (ω≪ω1), the term jω/ω1 is very small, so the magnitude is negligible, and the phase is essentially zero. As the frequency approaches ω1, leading to a -3 dB point in magnitude and a phase angle of 45°. For frequencies much higher than ω1 (ω≫ω1), the magnitude's slope changes to 20 dB/decade, and the phase settles at 90°.

Figure 1

Quadratic pole/zero:

The magnitude and phase angle of a quadratic pole is:

Equation 3

Equation 4

The amplitude plot for a quadratic pole has two parts: a flat response below the natural frequency ωn, and a -40 dB/decade slope above ωn, with the actual plot's peak varying with the damping factor ζ2. The phase plot for a quadratic pole decreases linearly with a slope of -90° per decade, starting at one-tenth of the natural frequency and ending at ten times that, influenced by the damping factor ζ2.

タグ

Transfer FunctionBode PlotMagnitude PlotCorner FrequencyBreak FrequencyPhase AngleSimple PoleQuadratic PoleFrequency ResponseDB decadeDamping FactorAmplitude PlotNatural Frequency

章から 9:

article

Now Playing

9.6 : Transfer function and Bode Plots-II

Frequency Response

268 閲覧数

article

9.1 : Network Function of a Circuit

Frequency Response

228 閲覧数

article

9.2 : Frequency Response of a Circuit

Frequency Response

198 閲覧数

article

9.3 : Gain

Frequency Response

149 閲覧数

article

9.4 : Bode Plots

Frequency Response

410 閲覧数

article

9.5 : Transfer function and Bode Plots-I

Frequency Response

279 閲覧数

article

9.7 : Bode Plots Construction

Frequency Response

635 閲覧数

article

9.8 : Series Resonance

Frequency Response

130 閲覧数

article

9.9 : Characteristics of Series Resonant Circuit

Frequency Response

188 閲覧数

article

9.10 : Parallel Resonance

Frequency Response

169 閲覧数

article

9.11 : Frequency Response of Op Amp Circuits

Frequency Response

254 閲覧数

article

9.12 : Passive Filters

Frequency Response

419 閲覧数

article

9.13 : Active Filters

Frequency Response

666 閲覧数

article

9.14 : Scaling

Frequency Response

209 閲覧数

article

9.15 : Design Example

Frequency Response

305 閲覧数

JoVE Logo

個人情報保護方針

利用規約

一般データ保護規則

研究

教育

JoVEについて

Copyright © 2023 MyJoVE Corporation. All rights reserved